Installation and Operating Manual1010 319867-000KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCEWHENEVER MAINTENANCE ADJUSTMENT OR SERVI
10 www.statewaterheaters.com For all side wall terminated, horizontally vented power vent, gas fueled water heaters installed in every dwelling, build
www.statewaterheaters.com 11FIGURE 3 WATER PIPING - MIXING VALVE USAGEThis appliance has been design certifi ed as complying with ANSI Z21.10.3/CSA 4
12 www.statewaterheaters.com and the physically or developmentally disabled. If anyone using hot water from this heater fi ts into one of these groups
www.statewaterheaters.com 13Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle. HAN
14 www.statewaterheaters.com When installing the heater, consideration must be given to proper location. Location selected should be as close to the w
www.statewaterheaters.com 15Screws ScrewsTopCasing (Front)FIGURE 7ScrewsFIGURE 8FIGURE 9After the heater has been positioned and the earthquake stra
16 www.statewaterheaters.com COMBUSTION AIR AND VENTILATIONA gas water heater cannot operate properly without the correct amount of air for combustio
www.statewaterheaters.com 17FIGURE 11B. ALL AIR FROM OUTDOORS: (See Figures 12, 13 and 14)The confi ned space should be provided with two permanent
18 www.statewaterheaters.com 6. Louvers and Grilles: In calculating free area, consideration should be given to the blocking effect of louvers, grille
www.statewaterheaters.com 19limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water disch
2 www.statewaterheaters.com TABLE OF CONTENTSSAFE INSTALLATION, USE AND SERVICE 3GENERAL SAFETY 4INTRODUCTION 6 Get To Know Your Water Heater - Gas
20 www.statewaterheaters.com The temperature-pressure relief valve must be installed directly into the fi tting of the water heater designed for the re
www.statewaterheaters.com 21 GAS PIPINGMake sure gas supplied is same type listed on model rating plate. The inlet gas pressure must not exceed 14
22 www.statewaterheaters.com a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with
www.statewaterheaters.com 23 VENT PIPE TERMINATIONSTREET ELBOW NORMAL ELBOWPREFERRED PRACTICE:90° LONG SWEEP ELBOW (LESS RESTRICTIVE)BACK TO BACK EL
24 www.statewaterheaters.com Vent piping must slope up from heater to termination a minimum of 1/8 in. (0.3cm) rise per 4 ft. (1.2m) of vent pipingTER
www.statewaterheaters.com 25 CONDENSATEThis water heater is a condensing unit and requires a drain to be located in close proximity to allow the con
26 www.statewaterheaters.com SEQUENCE OF INSTALLATIONSCut a length of PVC pipe about 3.5 in. (9cm) longer than the wall thickness at the opening. Glu
www.statewaterheaters.com 27VENT PIPING TO BE SLOPED (DOWN) TOWARD HEATER TO PREVENT WATER FROM COLLECTING.6 in. (15 cm) MIN. LENGTHATTACH 45° TERMI
28 www.statewaterheaters.com FIGURE 28A VENT USED IN A SPECIAL VENTING SYSTEM WITH POSITIVE VENT PRESSURE AND PASSING THROUGH A ROOF SHALL EXTEND AT L
www.statewaterheaters.com 29PRIMERIt is recommended that Tetrahydrofuran (THF) be used to prepare the surfaces of pipe and fi ttings for solvent weld
www.statewaterheaters.com 3Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.M
30 www.statewaterheaters.com D. Inspection, cleaning, priming Visually inspect the inside of the pipe and fi tting sockets and remove all dirt, gr
www.statewaterheaters.com 31 U.S. POWER VENT WARNINGVENT HOOD(S) MAY BEEXTREMELY HOTDURING OPERATION.FIGURE 31 CAUTIONTO PREVENT EXHAUSTING PRODUCTS
32 www.statewaterheaters.com ELECTRICAL CONNECTIONSThe water heater must be connected to a properly grounded electrical branch circuit. A dedicated
www.statewaterheaters.com 33OPERATING INSTRUCTIONS Changing the Standby StatusWhen the Standby Button is pressed, the Status changes to normal opera
34 www.statewaterheaters.com Numeric DisplayNumeric information such as temperature set-point, maintenance codes and error codes are displayed using
www.statewaterheaters.com 35 WIRING DIAGRAMObey local codes and electric utility requirements when you install or service the water heater.This app
36 www.statewaterheaters.com LIGHTING INSTRUCTIONS1. Set the thermostat to the lowest setting.2. Set the ON/OFF switch on the control panel to the “
www.statewaterheaters.com 37 HEAT CYCLE DEFINITIONSSTATE DESCRIPTIONPre-purge If the heat engine initial call-for-heat is successful (all checks are
38 www.statewaterheaters.com TEMPERATURE REGULATIONFIGURE 35It is recommended that lower water temperatures be used to avoid the risk of scalding. I
www.statewaterheaters.com 39Water TemperatureTime for 1st Degree Burn (Less Severe Burns)Time for Permanent Burns 2nd & 3rd Degree (Most Severe
4 www.statewaterheaters.com GENERAL SAFETY
40 www.statewaterheaters.com Water Circulation PumpA circulation pump is integrated into the heat engine for the Hybrid application. The pump serves
www.statewaterheaters.com 41 Line Voltage MonitorThe control monitors the line voltage provided to the system. If the line voltage is too low, the s
42 www.statewaterheaters.com CONSTANT OUTPUT TEMPERATURE CONTROLWhile the temperature regulation in the previous section describes the features of te
www.statewaterheaters.com 43 HOUSEKEEPINGVacuum around base of water heater for dust, dirt, and lint on a regular basis. VENTING SYSTEM INSPECTIONAt
44 www.statewaterheaters.com softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The u
www.statewaterheaters.com 45 SNOW ACCUMULATIONKeep the area around fl ue terminal free of snow and ice. The appliance will not function properly if
46 www.statewaterheaters.com • Disconnect the hoses joining the tank and the heat engine (upper hose is water outlet and lower hose is water inlet).•
www.statewaterheaters.com 47 DIAGNOSTIC DISPLAYBy simultaneously pressing the “Mode” and “down arrow” buttons for 3 seconds the unit will allow acc
48 www.statewaterheaters.com If an error code is displayed, or odd behavior of the unit occurs, the fi rst corrective action should be to “Cycle the Po
www.statewaterheaters.com 49Fault Code DisplayedDescription CauseLockout typeRemedyE15Blower speed abnormal.Blower speed is 200RPM below the target
www.statewaterheaters.com 5GENERAL SAFETYBreathing carbon monoxide can cause brain damage or death.Always read and understand instruction manual.• I
50 www.statewaterheaters.com Fault Code DisplayedDescription CauseLockout typeRemedyE33 Water Flow Valve Closed.The water valve did not open when atte
www.statewaterheaters.com 51These guidelines should be utilized by a qualifi ed service agent.Problem Possible Cause(s) What to doNOT ENOUGH HOT WATE
52 www.statewaterheaters.com Problem Possible Cause(s) What to doWHEN THE TAP IS OPENED, THERE IS NO HOT WATER OR THE HOT WATER TURNS COLD AND STAYS C
www.statewaterheaters.com 53 SERVICEIf a condition persists or you are uncertain about the operation of the water heater contact a qualifi ed service
54 www.statewaterheaters.com PARTS IDENTIFICATIONITEM # DESCRIPTIONA Baffl e, FlueB Hot Water Outlet Nipple (w/ Anode, Heat Trap)C T&P Relief Val
www.statewaterheaters.com 55RONMLKJIHGFEDCBATQSP12U107654321ZYXWV119813
56 www.statewaterheaters.com REPLACEMENT PARTSDESCRIPTION KIT #Drain valve 9000058015T&P relief valve 9003741005Anode/MG/NIP/HT 9004333005Anode/
www.statewaterheaters.com 57LIMITED RESIDENTIAL GAS WARRANTYTHIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY If the glass lined tank in this w
58 www.statewaterheaters.com NOTES
www.statewaterheaters.com 59NOTES
6 www.statewaterheaters.com Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free se
500 Tennessee Waltz Parkway, Ashland City, TN 37015Phone: 800-821-2017 • Fax: 800-644-9306Website: www.statewaterheaters.com
www.statewaterheaters.com 7
8 www.statewaterheaters.com FIGURE 1 GET TO KNOW YOUR WATER HEATER - GAS MODELS REPLACEMENT PARTS AND DELIMING PRODUCTSReplacement parts and recomm
www.statewaterheaters.com 9Capacity, Gas and Electrical CharacteristicsModel Approx. Capacity Input GasTypeGas Supply Pressure Manifold Pressure Ele